The electrically heated IceFree3 Anemometer's simple, robust design provides a proven and reliable solution in icing environments.
#3447
#2578
The IceFree3 signal output is a variable amplitude sine wave, where frequency is proportional to wind speed. Patented off-axis correction minimizes errors in measuring up-slope or down-slope winds. The internal heater is powered by 24 VAC and allows for an operating temperature range of -40°C to 80°C (-40 °F to 176 °F). The optional 120/240 VAC to 24 VAC Transformer - IceFree3 Sensors is available to step down 120/240 VAC grid power.
The IceFree3 Heated Anemometer comes with a 10 m potted cable that can be extended to your desired length using the Power Cable Kit - IceFree3 Sensor 2C, sold separately and available in 10 meter increments up to 90 meters.
IceFree3 Heated Anemometer | 10m (33') cable (#3447) | IceFree3 Heated Anemometer | 10m (33') cable, Calibrated (#2578) | |
---|---|---|
Description | ||
Sensor type | 3 cup heated anemometer | 3 cup heated anemometer |
Applications |
|
|
Sensor range | maximum rated wind speed is 90 m/s (200 miles per hour) | maximum rated wind speed is 90 m/s (200 miles per hour) |
Instrument compatibility | all NRG loggers | all NRG loggers |
Output signal | ||
Signal type | variable amplitude sine wave, frequency proportional to wind speed | variable amplitude sine wave, frequency proportional to wind speed |
Anemometer Transfer Function |
m/s = (Hz x 0.572) + 1.00 [miles per hour = (Hz x 1.28) + 2.24] |
m/s = (Hz x 0.572) + 1.00 [miles per hour = (Hz x 1.28) + 2.24] |
Sensor to Sensor Variation | 99.7% of sensors fall within 4.3% of stated transfer function (based on over 800 samples) | 99.7% of sensors fall within 4.3% of stated transfer function (based on over 800 samples) |
Calibration | available upon request - contact NRG for more information. | calibration report supplied |
Output signal range | 0 Hz to 155 Hz | 0 Hz to 155 Hz |
Response characteristics | ||
Distance constant (63% recovery) | n/a | 7.6 m (25 feet) |
Power requirements | ||
Heater supply voltage |
|
|
Heater supply current |
|
|
Installation | ||
Mounting | mounts to a 27 mm (1.05 inch) diameter (3/4 inch IPS) pipe with a 5/16 inch nut and bolt; cabling exits into mounting pipe | mounts to a 27 mm (1.05 inch) diameter (3/4 inch IPS) pipe with a 5/16 inch nut and bolt; cabling exits into mounting pipe |
Tools required | 13 mm (0.5 inch) nut driver | 13 mm (0.5 inch) nut driver |
Environmental | ||
Operating temperature range | -40 °C to 60 °C (-40 °F to 140 °F) | -40 °C to 60 °C (-40 °F to 140 °F) |
Operating humidity range | 0 to 100% RH | 0 to 100% RH |
Physical | ||
Connections |
Signal Cable
|
Signal Cable
|
Cable length |
|
|
Weight | 1.45 kg (3.2 pounds) | 1.45 kg (3.2 pounds) |
Dimensions |
|
|
Materials | ||
Cups | precision balanced aluminum with black anodized finish and heat-resistant black paint | precision balanced aluminum with black anodized finish and heat-resistant black paint |
Body | cast aluminum with black anodized finish and heat-resistant black paint | cast aluminum with black anodized finish and heat-resistant black paint |
Shaft | centerless ground, stainless steel | centerless ground, stainless steel |
Bearing | stainless steel ball bearings with application specific lubrication | stainless steel ball bearings with application specific lubrication |
Magnet | 4 pole ceramic | 4 pole ceramic |
Coil | single coil, shielded for ESD protection | single coil, shielded for ESD protection |
Cable |
|
|
Enclosure |
|
|
Heater | fully encapsulated, self-regulating | fully encapsulated, self-regulating |
Base | cast aluminum with black anodized finish and heat-resistant black paint | cast aluminum with black anodized finish and heat-resistant black paint |
For Software downloads and details click here